fluorometer ivf lab equipment microbiology laboratory equipment

  • 1500.00 piece
Min. Order: 1 piece FOB PRICE
Registered Supplier Direct Contact Inquiry via Message
Product Details
Selling Units:Single item;Place of Origin:China;
Warranty:1 Year;Color:Red;
Classification:OTHER;Model Number:FLUO-100;
Product name:fluorometer;Single package size:40X40X30 cm;
Single gross weight:8.0 KG;
Product Description

The Fluo-100 is a dual-channel fluorometer, it provides high-sensitive fluorescent detection when quantifying nucleic acids and proteins, simple and cost to operate Applications: 1. The sample is scarce and difficult in processing 2. The low quantity of DNA, RNA, or protein after extraction 3. The sample will be used in the expensive experiments: qPCR, PCR cloning, transfection, the next generation sequencing and etc.


Fluorometer technical background

Our nano series Micro-Spectrophotometer measure the concentration and purity of the sample, because it is able to measure the absorbance of the whole ingredient(such as DNA, RNA, oligos and so on) of the sample at 260nm, that may make the read inaccuracy. While the fluorometer measure the fluorescence intensity of the fluorescent reagent which combine with the target molecule to read the concentration of sample. Generally, the read is lower than Nano series products but much accuracy than it.

The sensitivity of Nano series products are above 5ng/ul, and while the fluorometer is 0.5pg/ul in measuring DNA concentration. It is important and necessary for the most applications to read the lower and accuracy concentration of the sample. Using the Fluo-100 fluorometer with the quantitation kit can measure the sample concentration rapidly, sensitively and accurately.

Features

1. Simple – 4.3 inch touch screen, small and easy to use.

2. Easy measurement within 3 sec for DNA, RNA, and protein.

3. High sensitivity – Lowest DNA detection limit is 0.5pg/ul.

4. Two optical channels – Equipped with two fluorescence channels for nucleic acid, protein quantitation in one detection.

5. Linear Dynamic Range – Five orders of magnitude.

6. Opening system – You can match the instrument with the reagent you choose.

7. It can save at most 1,000 data and output data by USB port.

8. Adapter: 0.5ml qPCR tube adapter 0.2ml qPCR tube adapter.


Detailed Images
Light source
LED
Dynamic range
Five orders of magnitude
Linear Dynamic Range
R >0.995
Detector
Photodiode
Repeatability
<1.5%
Stability
<1.5%
Sensitivity
dsDNA: 0.5ng/ml
Measurement speed
3s (Once)
Dimension (W×D×H)mm
194×155×72.5 mm
Weight (kg)
0.4Kg
                                                                                          Ordering information
Code
Description
Code
Description
AS-18010-00
Fluo-100A Fluorometer, DC12V 1A
RS-FL0101-S
RS-FL0101-M
RS-FL0101-L
High-sensitivity dsDNA Quantitation kits (100 assays)

High-sensitivity dsDNA Quantitation kits (200 assays)

High-sensitivity dsDNA Quantitation kits (1000 assays)
AS-18020-00
Fluo-100B Fluorometer, DC12V 1A
AS-18030-00
Fluo-100C Fluorometer, DC12V 1A
RS-FL0102-S
RS-FL0102-M
RS-FL0102-L
Broad-range dsDNA Quantitation kits (100 assays)

Broad-range dsDNA Quantitation kits (200 assays)

Broad-range dsDNA Quantitation kits (1000 assays)
AS-18011-01
Adapter for 0.5ml qPCR tube (Standard)
AS-18011-02
Adapter for 0.2ml qPCR tube (Options)
RS-FL0103-S
RS-FL0103-M
RS-FL0103-L
High-sensitivity ssDNA Quantitation kits (100 assays)

High-sensitivity ssDNA Quantitation kits (200 assays)

High-sensitivity ssDNA Quantitation kits (1000 assays)
HOW TO USE

Fluo-100 Simple, easy to use and applications

The Fluo-100 is a dual-channel fluorometer, it provides high-sensitive fluorescent detection when quantifying nucleic acids and proteins, simple and cost to operate.

Applications:

1. The sample is scarce and difficult in processing.

2. The low quantity of DNA, RNA, or protein after extraction.

3. The sample will be used in the expensive experiments: qPCR, PCR cloning, transfection, the next generation sequencing and etc.


+

Fluo-100 Quantitation kit operation


+
                                                                                Two detection models of Fluo-100
Code
Light
Excitation Filters
Emission Filters
Fluo-100A
UV
365±20nm
420-480nm (60nm)
Blue
460±20nm
525-570nm (45nm)
Fluo-100B
Blue
460±20nm
525-570nm (45nm)
Red
625±10nm
670-725nm (55nm)
Fluo-100C
Blue
460±20nm
525-570nm (45nm)
Green
525±20nm
575-640nm (65nm)

Fluo-100 Quantitation kit

High sensitivity of dsDNA Quantitation Kit: 0.2--100ng

High sensitivity of ssDNA Quantitation Kit: 1--200ng

Broad range of dsDNA Quantitation Kit: 100--1600ng

Protein Quantitation Kit is researching.

+
                                              Application of different fluorescence channel
Channel
Excitation Filters
Normal kits
Applications
UV channel
365±20nm
Hoechst 33258, 4-MU,
EnZCheK Caspase
Nuclear acid quantification, Plant GUS reporter gene detection, Poptosis detection
Blue channel
460±20nm
PicoGreen®, oligreen,RiboGreen®,
GFP, Protein, Fluorescein, Quant-iT™
dsDNA, ssDNA, RNA quantification, GFP gene detection, Fluorescein detection, Protein detection
Green channel
525±20nm
Rhodamine, Cy3, RFP Vybrant Cytotoxicity
Rhodamine detection, Cy-3 fluorescence labeling detection, RFP gene detection, Cell activity poison detection
Red channel
625±10nm
Cy5, Quant-iT RNA
Cy-5 fluorescence labeling detection, RNA quantification
+
+
You May Like
Laboratory Glassware High Borosilicate Clear Glass Stir Rod With Two Round Tips
Laboratory Glassware High Borosilicate Clear Glass Stir Rod With Two Round Tips
Glass Stirring Rod With Both Round Head Glass Stirring Rod With Two Round Head
vacuum or non-vacuum blood collection tube EDTA K2 K3 blood clot activator ESR tube
vacuum or non-vacuum blood collection tube EDTA K2 K3 blood clot activator ESR tube
Pet Plastic Glass Edta Blood Tube Collection Price Vacutainer Vacuum Edta K2 K3 Blood Collection Tube
Butterfly medical needle 21 G sterile
Butterfly medical needle 21 G sterile
Butterfly Needle 21 G Medical Butterfly Needle 21 G Sterile
Joan Lab Infrared Loop Sterilizer
Joan Lab Infrared Loop Sterilizer
Infrared Inoculating Ring Sterilizer Lab Infrared Inoculating Ring Sterilizer
0.5ml 1ml 1.5ml 2ml Gamma Ray Sterile PP Freezing Tube Plastic Test Tube Freezing Tube
Laboratory Glass 250ml Kipp Hydrogen Generator Equipment